Based on our
knowledge of fluid dynamics we developed for BP and the DTI an entirely
new design of compact fire monitor with a 30% longer throw than
the conventional "Rams Horn" design.
This offers
improved safety for the fire crews and delivers significantly more
water on target improving fire suppression and cooling.
The full size
bifurcated design was tested on the BP Lolair Fire Protection vessel
to prove its long throw capability. Aerial photographs clearly show
its improved performance over conventional monitors.
The design offers
potential for further development especially for delivering foam.
For more information,
please contact us.
|